Hydac FAM

Home Hydac Accumulators Coolers Filters Off-Line Test Contact

De-Watering & Filtration Unit

The Hydac FluidAqua Mobil (FAM) portable fluid purifier is a compact self contained purifying system designed to remove free and dissolved water, and free and dissolved air/gases and solid contaminants from lubricating, hydraulic, heat transfer fluids and insulating oils.

The unit is a mobile castor mounted design requiring only a minimal operating area close to the contaminated fluid reservoir.

It comes in a number of different models with a flow rate of between 15 & 70 litres minute and the option of heating

The FAM conditioning purifier removes 100% of free water and as much as 80% of dissolved water. It also removes 100% of free and entrained gases and up to 80% of dissolved gases. Particulate removal is achieved using the high Beta rated Dimicron type filter elements.

Advantages

Applications

The contamination of hydraulic fluids with water can either be caused by condensation or by penetration. Variations in temperature of the hydraulic tank lead to condensation. The penetration of water can be caused by defective cooling hoses, defective seals or external leakages into the system. In lubrication and hydraulic fluids water can occur in two different forms: free water (visible) dissolved water (not visible) Aquamicron®, centrifuges and condensation methods normally only separate free water, the FAMH separates both forms of water from the oil. While dewatering the fluid, dissolved gases are also removed. Thereby the lubricating properties are improved which extends oil life, reduces component wear rates, and eliminates production losses caused by breakdowns.

Nema 12 Standard Separation of 100% free and 90% dissolved water through vacuum dehydration Separation of particles with high contamination retention capacity Removal of 100% free and 95% dissolved gases Easy handling and automatic supervision of the PLC controlled process User friendly touch screen diagnostics Standard aquasensor JIC connections

  • Steel and rolling mills
  • Pulp and paper plants
  • Power generation plants
  • Tool machines / Plastic machines
  • Hydraulic operated presses
  • Oil conditioning

Dimensions

  1. Strainer
  2. Sight glass
  3. Solenoid valve inlet
  4. Vacuum chamber
  5. Vacuum pump
  6. Water carrier
  7. Air breather
  8. Vacuum regulation
  9. Fluid level indicator vacuum chamber
  10. Discharge pump
  11. Oil filter
  12. Drainage

 

Hydraulic Circuit

  1. Strainer
  2. Sight glass
  3. Solenoid valve inlet
  4. Vacuum chamber
  5. Vacuum pump
  6. Water carrier
  7. Air breather
  8. Vacuum regulation
  9. Fluid level indicator vacuum chamber
  10. Discharge pump
  11. Oil filter
  12. Drainage

 

Technical details

 

FAM - 15

FAM - 15

FAM - 30

FAM - 50

FAM - 70

Filter size

OLF-15

OLF-15

OLF-30

OLF-45

OLF-60 (1300 / 2600)

Filter element

N15DMxxx(1x)

N15DMxxx(1x)

N15DMxxx(2x)

N15DMxxx(3x)

N15DMxxx (OLF60)(4x)
1300 R xxx BN3HC/-KB
2600 R xxx BN3HC/-KB

Capacity of pressure vessel in l

20

20

40

60

78 (OLF 60)
12,5 (1300)
24 (2600)

Contamination capacity to ISO 4572

500 g

500 g

1000 g

1500 g

2000 g (OLF 60)
151 - 227 g (1300)
303 - 455 g (2600)

Flow rate l/min at 50 Hz

17

17

36

56

76

Operating pressure in bar

4,5

4,5

4,5

4,5

4,5

Viscosity range in mm²/s (with CS)

15-500(15-350)

15-500(15-350)

15-500(15-350)

15-500(15-350)

15-500(15-350)

Electrical power consumption in W

1900

1900

2700

3200

5100

Fluid temperature in °C (with CS)

10-80(10-70)

10-80(10-70)

10-80(10-70)

10-80(10-70)

10-80(10-70)

Typical de-watering speed l/h

1

1

1.7

2.2

2.6

 

For more information Click on the Hydac icon above and then contact Oil Solutions for all your requirements

  Information Available from Hydac or Oil Solutions

De-Watering & Filtration Unit ( 323 KB).

Fluid Service (PDF 969 KB);
Mobile Filtration Systems (PDF 641 KB);
Static Filtration Systems (PDF 1597 KB);